Modify an Alarm Template

<p class="shortdesc">If there is any change of alarm template information, you can modify it.</p> <section id="edit_template__steps_oft_qnz_3jb"><div class="tasklabel"><h2 class="doc-tairway">Procedure</h2></div><ol class="ol steps" id="edit_template__steps_oft_qnz_3jb"><li class="li step stepexpand"> <span class="ph cmd">Log in to the <a class="xref" href="/console/argus/overview" target="_blank">Argus Console</a>.</span> </li><li class="li step stepexpand"> <span class="ph cmd">In the left navigation pane, click <span class="ph uicontrol">Templates</span>.</span> </li><li class="li step stepexpand"> <span class="ph cmd">On the <span class="keyword wintitle">Alarm Template</span> page, click he drop-down button at the rear of the <span class="ph uicontrol">Type</span> to select the product.</span> <div class="itemgroup info"> <img class="image" id="edit_template__d30e51" src="https://obs-cn-shanghai.yun.pingan.com/pcp-portal/20201507091432-1eb49d65960a.png" width="500"> </div> </li><li class="li step stepexpand"> <span class="ph cmd">Find the alarm template needed to edit, then click <span class="ph uicontrol">Edit</span> in the <span class="ph uicontrol">Operations</span> column.</span> </li><li class="li step stepexpand"> <span class="ph cmd">On the <span class="keyword wintitle">Edit Alarm Template</span> page, you can modify the <span class="ph uicontrol">General Info</span> and <span class="ph uicontrol">Alarm Rules</span>.</span> <div class="itemgroup info"> <ul class="ul" id="edit_template__ul_jby_ynz_3jb"> <li class="li"><span class="ph uicontrol">General Info</span><table class="table frame-all" id="edit_template__table_ms5_bcw_jkb"><caption></caption><colgroup><col style="width:22.98850574712644%"><col style="width:77.01149425287358%"></colgroup><thead class="thead"> <tr class="row"> <th class="entry" id="edit_template__table_ms5_bcw_jkb__entry__1">Configuration item</th> <th class="entry" id="edit_template__table_ms5_bcw_jkb__entry__2">Description</th> </tr> </thead><tbody class="tbody"> <tr class="row"> <td class="entry" headers="edit_template__table_ms5_bcw_jkb__entry__1 "> <p class="p"><span class="ph uicontrol">Template name</span></p> </td> <td class="entry" headers="edit_template__table_ms5_bcw_jkb__entry__2 "> <p class="p">The name of the configured alarm template.</p> </td> </tr> <tr class="row"> <td class="entry" headers="edit_template__table_ms5_bcw_jkb__entry__1 "> <p class="p"><span class="ph uicontrol">Contact group</span></p> </td> <td class="entry" headers="edit_template__table_ms5_bcw_jkb__entry__2 "> <p class="p">The contact group that is to be informed when the alarm occurs.</p> <p class="p">Click <span class="ph uicontrol">Select Contact Group</span>, on the page that opens, check the contact group and click <span class="ph uicontrol">Finish</span>.</p> </td> </tr> </tbody></table></li> <li class="li"><span class="ph uicontrol">Alarm Rules</span>: modify or delete existing alarm rules and add new alarm rules. For more information of <span class="ph uicontrol">Static Rule</span> or <span class="ph uicontrol">Dynamic Threshold</span>, see the following descriptions.<table class="table frame-all" id="edit_template__table_gb2_dcw_jkb"><caption><span class="table--title-label">Table 1. </span><span class="title">Static rule configuration item description</span></caption><colgroup><col style="width:23.809523809523807%"><col style="width:76.19047619047619%"></colgroup><thead class="thead"> <tr class="row"> <th class="entry" id="edit_template__table_gb2_dcw_jkb__entry__1">Configuration item</th> <th class="entry" id="edit_template__table_gb2_dcw_jkb__entry__2">Description</th> </tr> </thead><tbody class="tbody"> <tr class="row"> <td class="entry" headers="edit_template__table_gb2_dcw_jkb__entry__1 "> <p class="p"><span class="ph uicontrol">Type of monitoring </span></p> </td> <td class="entry" headers="edit_template__table_gb2_dcw_jkb__entry__2 "> <p class="p">Select <span class="ph uicontrol">Static Rule</span>, define how the alarm system detects the monitoring data by configuring the specified function, and send the alarm notification when the monitoring data meets the alarm rule.</p> </td> </tr> <tr class="row"> <td class="entry" headers="edit_template__table_gb2_dcw_jkb__entry__1 "> <p class="p"><span class="ph uicontrol">Metric</span></p> </td> <td class="entry" headers="edit_template__table_gb2_dcw_jkb__entry__2 "> <p class="p">Configure the metric used in the alarm template.</p> <p class="p">Click <span class="ph uicontrol">Select Metric</span> and check metrics. Then click <span class="ph uicontrol">Finish</span>.</p> </td> </tr> <tr class="row"> <td class="entry" headers="edit_template__table_gb2_dcw_jkb__entry__1 "> <p class="p"><span class="ph uicontrol">Tag</span></p> </td> <td class="entry" headers="edit_template__table_gb2_dcw_jkb__entry__2 "> <p class="p">The tag of alarm rules. To supplement the monitoring item (metric), such as df.bytes.used (disk usage) need to have two tags, one is mount:: mount point, one is fstype: File system type.</p> </td> </tr> <tr class="row"> <td class="entry" headers="edit_template__table_gb2_dcw_jkb__entry__1 "> <p class="p"><span class="ph uicontrol">Point count</span></p> </td> <td class="entry" headers="edit_template__table_gb2_dcw_jkb__entry__2 " rowspan="2"> <p class="p">You may set the specific alarm policies according to the actual monitoring items. For example, if the monitoring item is CPU usage rate with the points of three and the statistical function average is >80%. when the average detected value of CPU usage rate in three consecutive statistical periods is over 80%, the alarm notification would be sent.</p> </td> </tr> <tr class="row"> <td class="entry" headers="edit_template__table_gb2_dcw_jkb__entry__1 "> <p class="p"><span class="ph uicontrol">Function</span></p> </td> </tr> <tr class="row"> <td class="entry" headers="edit_template__table_gb2_dcw_jkb__entry__1 "> <p class="p"><span class="ph uicontrol">Alarm level</span></p> </td> <td class="entry" headers="edit_template__table_gb2_dcw_jkb__entry__2 "> <p class="p">There are six alarm levels, including P1~P6 in decreasing order.</p> <ul class="ul" id="edit_template__d22e313"> <li class="li">P1: Fatal</li> <li class="li">P2: Relatively fatal</li> <li class="li">P3: Severe</li> <li class="li">P4: Relatively severe</li> <li class="li">P5: Warning</li> <li class="li">P6: Reminding</li> </ul> </td> </tr> <tr class="row"> <td class="entry" headers="edit_template__table_gb2_dcw_jkb__entry__1 "> <p class="p"><span class="ph uicontrol">Alarm times</span></p> </td> <td class="entry" headers="edit_template__table_gb2_dcw_jkb__entry__2 "> <p class="p">Times of sending alarm notifications.</p> </td> </tr> <tr class="row"> <td class="entry" headers="edit_template__table_gb2_dcw_jkb__entry__1 "> <p class="p"><span class="ph uicontrol">Remark</span></p> </td> <td class="entry" headers="edit_template__table_gb2_dcw_jkb__entry__2 "> <p class="p">Relevant description and remarks of the alarm rule.</p> </td> </tr> </tbody></table></li> </ul> </div> </li><li class="li step stepexpand"> <span class="ph cmd">After finishing, click <span class="ph uicontrol">Save Template</span>.</span> </li></ol></section>
Did the above content solve your problem? Yes No
Please complete information!

Call us

400-151-8800

Email us

cloud@pingan.com

Online customer service

Instant reply

Technical Support

cloud products